Language
189 4200 1700
Products Product Details
Product name:

20102G ADP-30K2

Listing date: 2017-05-10
  • Size drawings
  • Electrical specifications
  • Specification

 

20102G ADP-30K2

 

 

 

 

20102G ADP-30K2
outputModelADP-30K4ADP-30K2ADP-24K2ADP-30K9ADP-30K8ADP-30K5
DC voltage 
remark 2
24V12V12V9V8V5V
Rated current1.25A2.5A2A3A3A3A
Current range0~1.25A0~2.5A0~2A0~3A0~3A0~3A
Rated power (maximum)30W30W24W27W24W15W
Ripple and Noise (maximum) remark 3240mVp-p120mVp-p120mVp-p90mVp-p80mVp-p50mVp-p
Voltage precision remark 4±5.0%±5.0%±5.0%±5.0%±5.0%±5.0%
Linear adjustment rate 5±3.0%±3.0%±3.0%±3.0%±3.0%±3.0%
Load adjustment rate±5.0%±5.0%±5.0%±5.0%±5.0%±5.0%
Start and rise time remark 62.5S,30ms/100VAC(full load)
Maintain Time(Typ.)20ms/230VAC    10ms/115VAC(full load)
inputVoltage range100-240Vac
Frequency range50/60Hz
Efficiency(Typ.)88%87%86%83%83%
AC current0.8A/100VAC     0.5A/230VAC
Surge current (maximum)30A/230VAC
Leakage current (maximum)0.75mA/240Vac
ProtectionOverload120%~150% of rated output power
Protection mode: hiccup mode, load exception conditions can be automatically restored after removal.
Overvoltage28.8~31.2V14.4~15.6V14.4~15.6V10.8~11.7V9.6~10.4V
Protection mode: turn off the output voltage and resume after restart.
EnvironmentWorking temperature0~+40℃
Working humidity20~80%RH, no condensation
Storage temperature and humidity-30~+70℃,10~90%RH
temperature coefficient±0.03%/℃(0~40℃)
Vibration resistance10~300Hz, 1G 10 minutes / cycle, X, Y, Z axis 60 minutes each.
Safety regulationSafety specificationEN60950-1,CCC GB4943 and other authentication pass
andPressure resistanceI/P-O/P:3KVAC   I/P-FG:2KVAC
electromagnetismInsulation impedanceI/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/70% RH
Compatibility (remark 7)EMC emissionConforming to EN55022 class B,FCC PART 15,GB9254,GB17625.1

Electromagnetic compatibility immunityConforming to EN61000-4-2,3,4,5,6,8,11,A scale light industrial standard
ConnectorPlugOther models can be customized by customer requirements
wireOther models can be customized by customer requirements
Remarks1. If no specified, all specifications are measured at the input voltage of 230VAC, rated load and 25 C 70%RH ambient temperature.
2.DC voltage measurement method: under 50% load condition, measure at terminal socket point;
3.Ripple and noise measurement method: using a 12 twisted pair, while the terminal must be connected in parallel with the capacitance of 0.1uF and 47uF, and carry out the measurement under 20MHZ broadband.
4.Accuracy: including setting error, linear adjustment rate and load adjustment rate;
5.linear adjustment rate measurement method: under rated load, from low voltage to high voltage test;
6. the start-up time is measured in the cold starting state, and the continuous switch machine may extend the start-up time.
7.power supply is regarded as a part of the components in the system, and the electromagnetic compatibility related confirmation must be combined with the terminal equipment.



Hot Products / Related Products More
Copyright ©2005 - 2013 Guangzhou Dajing Technology Co., Ltd
犀牛云提供企业云服务